Our Intrinsically Safe Hall Effect sensors feature the same high-quality construction and materials as our standard Hall Effect speed sensors. They are designed and developed for each specific customer application. These sensors are certified to CSA (with NRTL/C), LCIE to ATEX (2014/34/EU) and IECEx for hazardous locations listed below.
- Features & Specifications
- Standard Models
Input Power
- 4.7 to 24 VDC regulated, 15 mA maximum @ no load
- Reverse polarity protected
Pulse Output Options
- TTL/CMOS (Standard); fanout of 5 TTL/CMOS loads\
- Open collector
- Supply tracking: logic 0: 0.4 VDC
- logic 1: (VS-0.2)xRL/(RL+2200)
Airgap
Up to 0.100″ dependent on target geometry and sensor construction
Up to 0.100″ dependent on target geometry and sensor construction
Interconnection Options
- Magnet that resists demagnetization
- Focusing tip
- Three (3) pin MIL-C-5015 type connector with gold plated pins; mates with MS3106-10SL-3S; other connector types upon request
- Pigtail with wires or cable
- NPT threaded body with wire or cable pigtail for explosion proof environments
Warranty
Unconditional one (1) year warranty if used within specifications
Unconditional one (1) year warranty if used within specifications
Orientation
Alignment of the sensor to target rotation is required for optimal performance, ensuring proper orientation of the hall effect element to the magnetic field
Alignment of the sensor to target rotation is required for optimal performance, ensuring proper orientation of the hall effect element to the magnetic field
Pin Connections
- Pin A (Red): Input Power (+)
- Pin B (White): Pulse Output (+)
- Pin C (Black): Common (-)
Physical Features
- Operating temperature:
-40°C to +125°C with connector
-40°C to +105°C with pigtail
NOTE: units that operate up to 150°C
are also available
- Storage temperature:
-40°C to +150°C with connector
-40°C to +105°C with pigtail - Body material: 300 series stainless steel
- Encapsulation: epoxy potting or hermetically sealed, welded construction
- High Shock and Vibration resistance (MIL-STD-202G METHOD 214A, Test Condition H)
Approvals
- Intrinsic Safety to CSA (with NRTL/C) for: (LINK TO 1102298)
- LCIE to ATEX (2014/34/EU) for Ex II 1 G; Ex ia IIC T4; Ex ia IIC T2; Ex ia IIA T4; Ex ia IIA T2
- IECEx for Ex ia IIC T4; Ex ia IIC T2; Ex ia IIA T4; Ex ia IIA T2
- CE compliant to EMC Directive 2004/108/EC for use in residential, commercial, light industrial and heavy industrial environments