This series of preamplifiers/signal conditioners is available in
a combination version that provides user selection of either variable reluctance VR or
RF sensor input.
When used with VR sensors they will accept low-level signals and provide hysteresis to eliminate
unwanted noise and interference. Operating range is 4 to 10,000 Hz. When used with RF sensors, they provide false pulsing safeguards,
air gaps up to 0.150", a frequency range of 2 to 5,000 Hz, as well as a precisely tuned carrier signal to allow for maximum signal
reliability.
Features and Specifications
Input Power:
Voltage: 8 to 30 VDC
Current draw: 25 mA @ 24 VDC
Reverse polarity protected
RF Sensor Input:
Modulation carrier frequency: 25 KHz
Input frequency: 2 Hz to 5 KHz
Maximum air gap: 0.150"
Preferred coil inductance: 1.0 mH +/- 10%
Max. distance from sensor to preamp: 100'
VR Sensor Input:
Input protected, RF and band pass filtered
Input frequency: 0 to 10 KHz
Trigger sensitivity: 4 mV RMS minimum (NOTE: at 4 mV frequency range 10 Hz to 3 KHz)
Input impedance: 40K ohms (nominal)
Maximum input signal: 600 volts RMS
Max. distance from sensor to preamp: 100'
Pulse Output Options:
All output options are user selectable
Open collector Vmos transistor, maximum OFF state voltage 30 VDC; maximum ON current 400 mA
TTL/CMOS; fanout of 5 TTL/CMOS loads
0 to 10 VDC square wave
Square wave tied to input voltage
Physical Dimensions:
Board diameter: 1.1"
+/- 0.1"
Height: 0.96" +/- 0.02"
Temperature Range:
Operating: -40°F to +185°F (-40°C to +85°C)
Units to 125°C also available
Storage: -40°F to +302°F (-40°C to +150°C)
Enclosures:
Unit is intended for mounting in an elbow conduit box such as Crouse-Hinds Model LBY15
Approvals:
CE compliant to EMC Directive 2004/108/EC for use in residential, commercial, light industrial
and heavy industrial environments
Warranty:
Unconditional one (1) year warranty if used within specifications